- 21 -
If the boiler is fitted with an automatic ignition, the ”START FUEL” must be so large that the fuel will
reach nearly up to the ignition nozzle; if not, you will have the same problem with the “START-UP
OXYGEN LIMIT”.
START FUEL
Press ”MENU”
START FUEL
AFTERRUN
ADJUST 1.60 SEC
Use the arrow keys to set the screw running period for the start portion, select a value from 0.03 and up to
52sec.
After selection of the wanted start portion press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.35 Afterrun.
Not in use in this standard control.
AFTERRUN
START FUEL 2-3
Therefore -
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.36 Start portion 2-3.
When the boiler are going from step 2 to 3, we add an adequate portion of fuel (”START FUEL 2-3”) to
enable full out-put as soon as possible.
If the boiler get to little fuel at this time, the temperature will drop to much, before it start raisung again.
If it gets to much, you will get black smoke from the chimney.
START FUEL 2-3
Press ”MENU”
START FUEL 2-3
BOILERTEMP START. ADJUST 1.60 SEC
Use the arrow keys to set the screw running period for the start portion, select a value from 0.03 and up to
52sec.
After selection of the wanted start portion press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.37 Boilertemp start.
It is possible to adjust the number of degrees dropping below set temp before the boiler starts up again
BOILERTEMP START.
Tryk ”MENU”
BOILERTEMP START
SMOKEFAN
ADJUST 003