- 17 -
Use the arrow keys to select the fan speed, you may choose between values from 001 to 080.
After selection of the wanted fan speed, press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.23 Oxygen % step 0.
The oxygen percentage is permanently measured in order to obtain the optimum combustion.
The measured oxygen content is the amount of rest oxygen in the fluegas. By a low output, it is difficult
to utilize the oxygen, this is why the wanted oxygen value is higher in the low output steps than in the
high output steps.
OXY STEP
0
Press ”MENU”
OXY STEP
0
OXY STEP
1
ADJUST 14 %
Use the arrow keys to select the oxygen percentage, select a value between 5 and 21 %.
After selection of the wanted oxygen % press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.24 Oxygen % step 1.
The oxygen % in step 1 should be set a little lower than in step 0, to obtain the optimum combustion.
OXY STEP
1
Press ”MENU”
OXY STEP 1
OXY STEP
2
ADJUST 12 %
Use the arrow keys to select the oxygen percentage, select a value between 5 and 21 %.
After selection of the wanted oxygen % press ”MENU”, and your choice has been saved.
Press ”
▼
” to proceed to the next parameter you wish to change – or press the ”START-UP” and the
“MENU” keys at the same time to finish.
6.25 Oxygen % step 2.
As a starting point, the oxygen % in step 2 should always be set at 10 %.
OXY STEP
2
Press ”MENU”
OXY STEP 2
OXY STEP
3
ADJUST 10 %
Use the arrow keys to select the oxygen percentage, select a value between 5 and 21 %.
After selection of the wanted oxygen % press ”MENU”, and your choice has been saved.