VIII - 26
KRONE operation terminal Beta
To adjust sensor B9/B10 bale diameter (COMPRIMA
V 150; V180):
Before you readjust or correct the setting of the
sensor (7) „B9/B10 bale diameter,“ make certain
the stop (6) for the soft core setting is in Pos. II or
III (soft inner bale core). A setting may only be
made on the sensor (7) in this position.
Soft core setting:
•
Open the bale chamber.
•
Remove the screw (5).
•
Move the stop (6) to Pos. II or III (soft inner bale
core).
•
Assemble and tighten the screw (5).
•
Close the bale chamber.
Make certain the feeder rake (4) is
resting on the stop (6). (If necessary
release tension on floor conveyor)
The bale chamber must be closed and
empty.
Dimension X must be 105 mm after
the setting is made.
Storing a value
•
Press the
key, the set position is saved, the
icon appears in the display.
COMPRIMA F 155
RPK50700
state
1,0V
1,3V
4-2
1,3
5,0V
1,5V
OK
0
1
2
L
B9
III
COM00011_1
5
4
6
7
4
X
VPN00012_4
6