1-7
Cleaning the roller of the humidification section
(Relay conveyance unit RU-511)
1
Open the front door of the relay
conveyance unit.
2
Hold the handle [HM1], and pull out the
humidification unit.
3
Hold the lever [HM2], and open the paper
path.
4
Moisten the cleaning pad with isopropyl
alcohol, and clean the roller.
5
Hold the handle [HM1], and move the humidification unit to the initial position.
6
Close the front door of the relay conveyance unit.