3-55
20
Stack 10 sheets of blank paper whose type is the same as that of the paper where
chart has been printed, and place the printed chart on top of it.
21
When the following screen is displayed,
place the spectrophotometer on the
patch at the top in the upper left, and
press the button for the
spectrophotometer. When beep sounds,
check that the read patch is displayed on
the screen.
Tips
For i1Pro2/ES-2000, install the positioning target to the
spectrophotometer before you measure the color.
22
Continuously, place the
spectrophotometer on the next right
patch, and press the button for the
spectrophotometer. Measure all the
patches in the same operation.
If you place the spectrophotometer on the wrong
place (patch), click the
button to go back to
the previous patch position.
The white portion where it is displayed that
nothing is printed is also part of the patch. Do not
forget to measure it. If not measured, an error will
occur.
23
When you are finished with the chart
measurement, click [Close].