2-9
bizhub PRESS C1100/C1085
2
11
Check the length of [2], [4], [6], and [8] of
the charts that are output as the second
and third sheet.
Write down the measured lengths so that you do
not forget them.
When the length of [2], [4], [6], and [8] is within the
following range, press [Close] and then press [OK]
to exit the adjustment.
When the length of [2], [4], [6], and [8] is out of the
following range, measure [1], [3], [5], and [7], and
go to the next step.
[2]: 200mm±0.3mm
[4]: 200mm±0.3mm
[6]: 200mm±0.3mm
[8]: 200mm±0.3mm
12
Press each point number, then enter the
measured length using the keypad on the
screen.
To reset a value, press [Clear].
13
When entry processing is completed,
press [Adjustment Start].
[ 1 ]
[ 5 ]
[ 7 ]
[ 6 ]
[ 8 ]
[ 2 ]
[ 3 ]
[ 4 ]
[ 1 ]