2-27
bizhub PRESS C1100/C1085
2
5
Press [Back].
6
Check the back side magnification
difference from the back side images
that are output as the second and third
sheet among the output jobs in step 1.
Pile the output jobs so that the front side of one
sheet faces up, and the back side of another sheet
faces up. Compare the image interval of the front
side and the image interval of the back side.
When the image interval of the front side is
different from the image interval of the back side,
enter the adjustment value in [Vertical] (crosswise
direction) and [Horizontal] (paper feed direction) at
the [back] screen.
Example of adjusting the image magnification:
If the image interval on the front side is 400 mm,
and the image interval on the back side is 401 mm,
enter [-0.25 %] in the adjustment value.
NOTICE
When you invert the paper, be sure that the crosswise
direction becomes the rotation axis.
Tips
The adjustment value changes 0.01% on a 1-step basis.
Adjustment Range: [Vertical] –1.00 to +1.00, [Horizontal] –
0.80 to +0.20
When [User Setting] - [Common Setting] - [Back Side
Magnification Adjustment] - is configured to [OFF],
[Horizontal] cannot be configured.
7
After the adjustment is completed, press
[OK].