3-70
bizhub PRESS C1100/C1085
3
11
Securely place EFI Spectrometer ES-
1000/2000 in the calibration cradle, then
click [Continue].
12
Stack 10 sheets of blank paper whose type is the same as that of the paper where
chart has been printed, and place the printed chart on top of it.
13
Follow the instructions on the
measurement window to measure color
strips in sequence.
-
Hold down the measurement button of EFI
Spectrometer ES-1000/2000. After you hear a
beep, slide it while holding down the
measurement button.
Slide EFI Spectrometer ES-1000/ES-2000 to
the bottom of strip, then release the
measurement button.
-
For details about how to use EFI
Spectrometer ES-1000/2000, refer to the
manual supplied with the spectrophotometer.
14
In the same way, measure all colors.
-
When a strip is measured successfully, a
check mark is displayed at the top of the color
name, and
is displayed for the color to be
measured next.
15
When all the patches have been read
successfully, click [Continue].