BOTH SIDES ADJUSTMENT
About both sides adjustment
To maintain stable both sides accuracy against a change in ambient temperature or humidity, a change of this machine
conditions, or a change of the both sides accuracy due to the paper type, perform the both sides adjustment at
periodic intervals.
After you understand the both sides adjustment flow (timing, method, and order), perform the necessary adjustment.
There are three types of both sides adjustment flows as follows.
Adjustment flow
when using a new paper brand, a new paper weight, or a new paper size
)
Adjustment timing
-
When you use a new paper brand, a new paper weight, or a new paper size
)
Adjustment order
Reference
For details of each adjustment item, refer to "Contents of both sides adjustment items" (
Page 2-3
).
Type of adjustment flow
Adjustment timing
Adjustment flow when using a
new paper brand, a new paper
weight, or a new paper size
When you use a new paper brand, a new paper weight, or a new paper size
Regular adjustment flow
When you change the brand, weight, or size of the paper inside the tray
Adjustment flow for each job
•
Before you output a job that the both sides accuracy is important
•
Before you output a job that the printing area is large
•
When you are not satisfied with the both sides accuracy (when you want to
raise the both sides accuracy)
Order
Adjustment item
Reference
1
Placing paper
P.2-3
2
Front side adjustment
P.2-6
3
"Gap adjustment" or "Scan measurement adjustment"
P.2-11
(When not using
PF-708 scanner)
P.2-16
(When using PF-
708 scanner)
4
Registering the paper profile
P.2-24
Summary of Contents for bizhub PRESS C1085
Page 1: ...2016 6...
Page 27: ...2 15 bizhub PRESS C1100 C1085 2 13 Press Exit Print Mode 14 Press OK to exit the adjustment...
Page 112: ...3 71 16 Click Apply Close The calibrated measurement values are applied...
Page 113: ...3 72 bizhub PRESS C1100 C1085 3 Blank Page...
Page 114: ...2016 2016 6...