3-52
bizhub PRESS C1100/C1085
3
8
Press
Start
on the
control panel
.
The color chart is output for measurement using
the spectrophotometer.
9
Press [Exit PrintMode].
10
Press [Return], and return to the [Density
Balance Adjustment Menu] screen.
11
On the computer where the X-rite Measure tooL. l has been installed, select [Start] -
[All Programs] - [X-Rite] - [ProfileMaker Pro 5.0.10] - [MeasureTool].
12
When the following message is
displayed, click [OK].