3-17
4
Select the [Type3] of "Measure
Spectrophotometer-3", and press [Print
Mode].
5
Press [Quality Adj.].
6
Press [Screen Pattern] and select the
screen that is changed at "Change
setting of Custom Screen" in the
adjustment items (screen for Density
balance adjustment) .
Tips
[Stochastic] is unavailable.
7
Select paper for chart output.
Tips
Load 12
e
18
w
, SRA3
w
, 11
e
17
w
, or A3
w
paper in a
tray, then select that tray.
Load the paper of paper type and weight that you want to
register on the density balance adjustment data into the
target tray.
This machine selects the density balance adjustment data
to apply a job in accordance with the following priority.
Priority 1: Screen > Priority 2: Paper Type > Priority 3:
Weight > Priority 4: Registered Order
(If there is no density balance adjustment data for the
screen that corresponds to a job, the job is output without
correcting its density balance.)