90
484164/A
9
If relevant for your transducer installation, provide the accurate physical location of the
transducer with reference to the vessel’s coordinate system.
Use the centre of the transducer face as reference, and define the offset values related
to the
Ship Origin
.
The installation angles relevant for the transducer must also be defined. These values
were recorded during the installation, and they define the direction of the transducer
face.
Note
It is very important that the transducer installation angles are measured and recorded
accurately during the installation. These angles must be accurately defined in the
operating software. Incorrect angles will greatly reduce the data accuracy.
a
Select the offset value on the X axis (fore-and-aft direction) from the
Ship Origin
.
Adjust with a positive value for X if the transducer is located ahead of the ship
origin.
b
Select the offset value on the Y axis (athwartship) from the
Ship Origin
. Adjust
with a positive value for Y if the transducer is located on the starboard side
of the ship origin.
c
Select the offset value on the Z axis (vertical) from the
Ship Origin
. Adjust with a
positive value for Z if the transducer is located under the ship origin.
10
Provide the accurate physical rotation of the transducer with reference to the vessel’s
coordinate system.
These settings may be required to adjust for deviation.
a
Specify an angle (in degrees) to compensate for any deviation from the X axis
(fore-and-aft direction) in the vessel coordinate system.
b
Specify an angle (in degrees) to compensate for any deviation from the Y axis
(athwartship direction) in the vessel coordinate system.
c
Specify an angle (in degrees) to compensate for any deviation from the Z axis
(vertical direction) in the vessel coordinate system.
11
Select
Add
to save the information you have provided.
The transducer is added to the list in the
Installed Transducers
box.
12
Repeat for each transducer that you want to install.
13
Continue your work in the
Installation
dialog box, or select
OK
to close it.
Result
Once a transducer has been installed, it is listed in the
Installed Transducers
box. To see the
information you have collected about the transducer, select the relevant transducer in the list.
Simrad CP200-5C Installation Manual
Summary of Contents for Simrad CP200-5C
Page 1: ...Photo by Gatis Marcinkevics kongsberg com simrad Simrad CP200 5C INSTALLATION MANUAL ...
Page 2: ......
Page 55: ...484164 A 53 Related topics Preparations page 22 Acoustic noise page 45 Preparations ...
Page 58: ...56 484164 A Related topics Preparations page 22 Simrad CP200 5C Installation Manual ...
Page 101: ...484164 A 99 Drawing file ...
Page 110: ... 2022 Kongsberg Maritime ...