70
484164/A
3
Open the shipping box.
Note
Be careful! Do not use heavy tools. Do not use excessive force. Make sure that you do
not damage the transducer or the cable.
4
Lift the transducer straight up and out of the box.
Note
DO NOT lift it by the cable!
5
Place the transducer on the cart for transport to the mounting location.
6
Transport the transducer carefully to its mounting location.
Related topics
Installing the transducer, page 57
Drawing file, page 94
Installing the transducer cable
When the transducer has been placed under its mounting location, the cable can be pulled
through the cable gland and bushing, and then through the steel conduit up to the transceiver.
Prerequisites
Before you can do this task, the following prerequisites must be met:
• All relevant work instructions, procedures and standards must be available.
• The bushing has been installed.
• The steel conduit is mounted with all installation work finalized.
• All relevant drawings have been approved by the classification society.
• All relevant personnel (skilled shipyard workers, ship electricians) and their tools must
be available.
You must be equipped with a standard set of tools. This tool set must comprise the normal
tools for electronic and electromechanical tasks. This includes different screwdriver types,
pliers, spanners, a cable stripper, a soldering iron, etc. We recommend that all tools are
demagnetized to protect your equipment. The following specific consumables are required
for this task:
• Fish tape
Simrad CP200-5C Installation Manual
Summary of Contents for Simrad CP200-5C
Page 1: ...Photo by Gatis Marcinkevics kongsberg com simrad Simrad CP200 5C INSTALLATION MANUAL ...
Page 2: ......
Page 55: ...484164 A 53 Related topics Preparations page 22 Acoustic noise page 45 Preparations ...
Page 58: ...56 484164 A Related topics Preparations page 22 Simrad CP200 5C Installation Manual ...
Page 101: ...484164 A 99 Drawing file ...
Page 110: ... 2022 Kongsberg Maritime ...