66
484164/A
A
Bushing, penetrates the hull plating
B
Washers
C
Rubber gasket
D
Packing nipple
Procedure
1
Make a suitable hole for the bushing.
2
Weld the bushing to the steel plate.
3
Verify the quality of the weld.
4
If relevant, allow the maritime authority and/or classification society to inspect and
approve the installation.
Further requirements
Before you can pull the transducer cable through the cable gland, the steel conduit must be
installed.