484164/A
67
Designing, manufacturing and mounting the
steel conduit
A steel conduit is used to protect the transducer cable. The conduit serves two purposes. It
will protect the cable, and shield it from electric noise. Depending on how the steel conduit
is terminated over the transducer, it may also secure the watertight integrity of the vessel.
Prerequisites
To design, manufacture and mount the steel
conduit, the following prerequisites must be
met:
• All relevant vessel and transducer drawings
must be available.
• All relevant work instructions, procedures
and standards must be available.
• The physical location of the transducer has
been determined.
• The installation method has been
determined.
• The cable gland has been installed.
• All relevant personnel (naval architects,
designers, skilled shipyard workers) and
tools must be available.
Illustration:
A
Service access (optional)
B
To transceiver
C
Steel conduits
D
Bushing, penetrates the hull plating
E
Washer
F
Rubber gasket
G
Packing nipple
H
Cable service loop over the transducer
Context
The installation shipyard must provide all necessary design and installation drawings, as
well as the relevant work standards and mounting procedures. If required, all documents
Summary of Contents for Simrad CP200-5C
Page 1: ...Photo by Gatis Marcinkevics kongsberg com simrad Simrad CP200 5C INSTALLATION MANUAL ...
Page 2: ......
Page 55: ...484164 A 53 Related topics Preparations page 22 Acoustic noise page 45 Preparations ...
Page 58: ...56 484164 A Related topics Preparations page 22 Simrad CP200 5C Installation Manual ...
Page 101: ...484164 A 99 Drawing file ...
Page 110: ... 2022 Kongsberg Maritime ...