Installation Manual
M300-62/rev.2
41
establish RS-422 communication between the MRU and the Processing
Unit. Otherwise there will be no communication between these two
components.
Note
The junction box housing is grounded to earth through the screws for
mounting the box to the wall or floor. Please note that if the foundation on
which the junction box is mounted, is NOT connected to earth, one of the
junction box mounting screws has to be connected to earth by connecting a
wire from the screw to an object that is connected to earth.
|-----------------------------User side x1-----------------------------|
pin signal description
pin signal description
1
PWRIN+ power +
23 XIN to MRU
2
PWRIN- power gnd 24 LGND gnd ref.aux.+dig
3
TX+ from MRU 27 SHUTOFF of MRU
4
TX- -"-
5
RX+ to MRU
6
RX- -"-
6
Connect the cables for output data from Seapath to external equipment to the Com
ports 1 and 2 or the terminals Com9 to Com14, analog output signals or the
Ethernet connection.
Note
Cable with shield has to be used in order to fulfil the Seapath power and
EMC requirements.
7
Connect the 110/230 V AC ship's power supply to the power connector at the rear
of the Processing Unit.
8
Connect the 110/230 V AC ship's power supply to the power connector at the rear
of the HMI Unit.
9
Connect the cable from the monitor, PC mouse and the keyboard to the
corresponding connectors at the rear of the HMI Unit.
10
Connect the monitor for the HMI Unit to 110/230V AC ship power.
Summary of Contents for Seapath 320
Page 1: ...Seapath 320 Installation Manual ...
Page 20: ...Seapath 320 4 M300 62 rev 2 ...
Page 42: ...Seapath 320 26 M300 62 rev 2 ...
Page 98: ...Seapath 320 82 M300 62 rev 2 ...
Page 100: ...Seapath 320 84 M300 62 rev 2 5 1 Processing and HMI Units ...
Page 101: ...Installation Manual M300 62 rev 2 85 ...
Page 102: ...Seapath 320 86 M300 62 rev 2 5 2 Antenna bracket ...
Page 103: ...Installation Manual M300 62 rev 2 87 5 3 MRU and mounting bracket ...
Page 104: ...Seapath 320 88 M300 62 rev 2 ...
Page 105: ...Installation Manual M300 62 rev 2 89 5 4 MRU junction box ...
Page 107: ...Installation Manual M300 62 rev 2 91 5 6 6 U cabinet dimensions ...
Page 108: ...Seapath 320 92 M300 62 rev 2 ...
Page 126: ...Seapath 320 110 M300 62 rev 2 ...
Page 127: ...Installation Manual M300 62 rev 2 111 ...
Page 128: ...Seapath 320 112 M300 62 rev 2 ...
Page 129: ...Installation Manual M300 62 rev 2 113 ...
Page 130: ...Seapath 320 114 M300 62 rev 2 ...
Page 133: ...Installation Manual M300 62 rev 2 117 APPENDIX D COAX CABLE SPECIFICATION ...
Page 134: ...Seapath 320 118 M300 62 rev 2 ...
Page 135: ...Installation Manual M300 62 rev 2 119 APPENDIX E RG 214 SPECIFICATIONS ...
Page 136: ...Seapath 320 120 M300 62 rev 2 ...
Page 152: ...Seapath 320 136 M300 62 rev 2 ...