Flame retardation ............................................................................................ IEC 332-3/A
2.11.3
GNSS antenna cables (Coax)
Type ................................................................................................. ½"-Superflex 50 BHF
Attenuation ................................................................................ 14 dB/100 m (at 1.6 GHz)
Maximum length (each cable) ...................................................................................100 m
Diameter ............................................................................................................... 13.2 mm
Minimum bend radius .............................................................................................. 32 mm
Flame retardation ................................................... CATV, UL1581, IEC 332-3, IEEE383
Coax connectors ..................................................................... Huber+Suhner 11 N-50-9-9
If the antenna cables are not delivered by Kongsberg Seatex, make sure that the cables
meet the following electrical specifications:
Insertion loss (max.)
15 dB (at 1.6 GHz)
Characteristic impedance
50 Ohm (nominal)
DC resistance (max.)
0.5 Ohm ground braid and centre conductor
Table 1 GNSS antenna cable specification
The antenna connectors on the Processing Unit are of N-type male. On the GNSS
antennas both TNC-type female and N-type female are available. Optionally, an
interconnection cable for transfer of connector type from TNC on the antenna to N-type
on the antenna cable, can be delivered.
Summary of Contents for Seapath 320
Page 1: ...Seapath 320 Installation Manual ...
Page 20: ...Seapath 320 4 M300 62 rev 2 ...
Page 42: ...Seapath 320 26 M300 62 rev 2 ...
Page 98: ...Seapath 320 82 M300 62 rev 2 ...
Page 100: ...Seapath 320 84 M300 62 rev 2 5 1 Processing and HMI Units ...
Page 101: ...Installation Manual M300 62 rev 2 85 ...
Page 102: ...Seapath 320 86 M300 62 rev 2 5 2 Antenna bracket ...
Page 103: ...Installation Manual M300 62 rev 2 87 5 3 MRU and mounting bracket ...
Page 104: ...Seapath 320 88 M300 62 rev 2 ...
Page 105: ...Installation Manual M300 62 rev 2 89 5 4 MRU junction box ...
Page 107: ...Installation Manual M300 62 rev 2 91 5 6 6 U cabinet dimensions ...
Page 108: ...Seapath 320 92 M300 62 rev 2 ...
Page 126: ...Seapath 320 110 M300 62 rev 2 ...
Page 127: ...Installation Manual M300 62 rev 2 111 ...
Page 128: ...Seapath 320 112 M300 62 rev 2 ...
Page 129: ...Installation Manual M300 62 rev 2 113 ...
Page 130: ...Seapath 320 114 M300 62 rev 2 ...
Page 133: ...Installation Manual M300 62 rev 2 117 APPENDIX D COAX CABLE SPECIFICATION ...
Page 134: ...Seapath 320 118 M300 62 rev 2 ...
Page 135: ...Installation Manual M300 62 rev 2 119 APPENDIX E RG 214 SPECIFICATIONS ...
Page 136: ...Seapath 320 120 M300 62 rev 2 ...
Page 152: ...Seapath 320 136 M300 62 rev 2 ...