Installation Manual
M300-62/rev.2
9
2.4.2
HMI Unit
Enclosure material ............................................................................................ Aluminium
Operating temperature range .................................................................. -15 °C to +55 °C
3
Recommended operating temperature .................................... Room temperature (+20 °C)
Storage temperature ................................................................................. -20 °C to +70 °C
Operating humidity ................................................................. Max. 95 % non-condensing
Storage humidity ........................................................................................ Less than 55 %
Ingress protection front ............................................................................................... IP 42
Ingress protection rear ................................................................................................ IP 21
2.4.3
Monitor, 17-inch LCD
Operating temperature range ............................................................................ 5 to +40 °C
Relative humidity .............................................................................................. 20 to 80 %
2.4.4
MRU Unit
Enclosure material ............................................................................. Anodised aluminium
Enclosure protection ................................................................................................... IP-66
Operating temperature range ........................................................................... -5 to +55 °C
Operating humidity (max) ......................................................................... Sealed, no limit
Storage temperature range ............................................................................. -20 to +70 °C
Storage humidity ....................................................................................... Sealed, no limit
Max allowed vibration operational (10 – 2000 Hz continuous) .............................0.5 m/s
2
Max allowed vibration non-operational (0 – 200 Hz continuous)...........................20 m/s
2
Max shock non-operational (10 ms peak) ...........................................................1000 m/s
2
2.4.5
GNSS antenna
Operating temperature range ................................................................... -40 °C to +85 °C
Ingress protection ..................................................................................... IP X6 and IP X7
3
Operating temperature up to +55 ºC for 10 hours.
Summary of Contents for Seapath 320
Page 1: ...Seapath 320 Installation Manual ...
Page 20: ...Seapath 320 4 M300 62 rev 2 ...
Page 42: ...Seapath 320 26 M300 62 rev 2 ...
Page 98: ...Seapath 320 82 M300 62 rev 2 ...
Page 100: ...Seapath 320 84 M300 62 rev 2 5 1 Processing and HMI Units ...
Page 101: ...Installation Manual M300 62 rev 2 85 ...
Page 102: ...Seapath 320 86 M300 62 rev 2 5 2 Antenna bracket ...
Page 103: ...Installation Manual M300 62 rev 2 87 5 3 MRU and mounting bracket ...
Page 104: ...Seapath 320 88 M300 62 rev 2 ...
Page 105: ...Installation Manual M300 62 rev 2 89 5 4 MRU junction box ...
Page 107: ...Installation Manual M300 62 rev 2 91 5 6 6 U cabinet dimensions ...
Page 108: ...Seapath 320 92 M300 62 rev 2 ...
Page 126: ...Seapath 320 110 M300 62 rev 2 ...
Page 127: ...Installation Manual M300 62 rev 2 111 ...
Page 128: ...Seapath 320 112 M300 62 rev 2 ...
Page 129: ...Installation Manual M300 62 rev 2 113 ...
Page 130: ...Seapath 320 114 M300 62 rev 2 ...
Page 133: ...Installation Manual M300 62 rev 2 117 APPENDIX D COAX CABLE SPECIFICATION ...
Page 134: ...Seapath 320 118 M300 62 rev 2 ...
Page 135: ...Installation Manual M300 62 rev 2 119 APPENDIX E RG 214 SPECIFICATIONS ...
Page 136: ...Seapath 320 120 M300 62 rev 2 ...
Page 152: ...Seapath 320 136 M300 62 rev 2 ...