Installation Manual
M300-62/rev.2
21
LAN 2, 3 and 4 at the rear
. These LANs are of high capacity (10/100/1000 Mbps)
and are of type auto crossover and auto negation. Below is the pin wiring for these
LANs connected to different network capacities:
10/1000 or 100/1000 Mbps Ethernet
1000/1000 Mbps Ethernet
Pin no.
Signal
Description
Pin no.
Signal
Description
1
TX_DA-
Transceive data +
1
BI_DA+
Bi-directional pair +A
2
TX_DA-
Transceive data -
2
BI_DA-
Bi-directional pair -A
3
RX_DB+
Receive data +
3
BI_DB+
Bi-directional pair +B
4
4
BI_DC+
Bi-directional pair +C
5
5
BI_DC-
Bi-directional pair -C
6
RX_DB-
Receive data -
6
BI_DB-
Bi-directional pair -B
7
7
BI_DD+
Bi-directional pair +D
8
8
BI_DD-
Bi-directional pair -D
Table 11 Pin layout for LAN 2, 3 and 4 Ethernet ports
To connect the Processing Unit network, use twisted pair (TP) cable with RJ-45
connectors. To comply with the IEC 60945 standard shielded (screened) cable has to be
used. Recommended cable type is CAT-5e. Category 5e cable is an enhanced version of
Category 5 that adheres to more stringent standards. It is capable of transmitting data at
speeds of up to 1000 Mbps (1 Gigabit per second). The maximum length of the cable
that can be used is 100 metres (328 ft).
2.12.3
LED indicators Processing Unit
At the front of the Processing Unit there are four LED indicators. The LED to the left
indicates power and software status, the second to the left indicates MRU status, while
the LED to the right indicates network card status. The last LED has for the moment no
function and will always be turned off.
Figure 5 Front panel of Processing Unit
Summary of Contents for Seapath 320
Page 1: ...Seapath 320 Installation Manual ...
Page 20: ...Seapath 320 4 M300 62 rev 2 ...
Page 42: ...Seapath 320 26 M300 62 rev 2 ...
Page 98: ...Seapath 320 82 M300 62 rev 2 ...
Page 100: ...Seapath 320 84 M300 62 rev 2 5 1 Processing and HMI Units ...
Page 101: ...Installation Manual M300 62 rev 2 85 ...
Page 102: ...Seapath 320 86 M300 62 rev 2 5 2 Antenna bracket ...
Page 103: ...Installation Manual M300 62 rev 2 87 5 3 MRU and mounting bracket ...
Page 104: ...Seapath 320 88 M300 62 rev 2 ...
Page 105: ...Installation Manual M300 62 rev 2 89 5 4 MRU junction box ...
Page 107: ...Installation Manual M300 62 rev 2 91 5 6 6 U cabinet dimensions ...
Page 108: ...Seapath 320 92 M300 62 rev 2 ...
Page 126: ...Seapath 320 110 M300 62 rev 2 ...
Page 127: ...Installation Manual M300 62 rev 2 111 ...
Page 128: ...Seapath 320 112 M300 62 rev 2 ...
Page 129: ...Installation Manual M300 62 rev 2 113 ...
Page 130: ...Seapath 320 114 M300 62 rev 2 ...
Page 133: ...Installation Manual M300 62 rev 2 117 APPENDIX D COAX CABLE SPECIFICATION ...
Page 134: ...Seapath 320 118 M300 62 rev 2 ...
Page 135: ...Installation Manual M300 62 rev 2 119 APPENDIX E RG 214 SPECIFICATIONS ...
Page 136: ...Seapath 320 120 M300 62 rev 2 ...
Page 152: ...Seapath 320 136 M300 62 rev 2 ...