Seapath 320
12
M300-62/rev.2
2.9
Data inputs
2.9.1
Processing Unit
DGPS corrections ................................................................. RTCM-SC104 v. 2.2 and 2.3
...................................................................................................................... Trimble CMR
DGLONASS corrections ................................................................... RTCM-SC104 v. 2.2
Gyro compass ............................................................. NMEA 0183 HEHDT and HEHRC
............................................................................................. Robertson LR22 BCD format
2.10
Compass safe distance
2.10.1
Processing Unit
Standard compass (mounted in 6U cabinet) ...............................................................2.6 m
Note
If the Processing Unit is not marked with a compass safe distance label,
the unit shall be placed five metres from both the steering compass and the
standard compass.
2.11
Cables
2.11.1
MRU cable
Type ................................................................................................................MRU-E-CS1
............................................................................ Heavy duty screened, 14 x 2 x 0.25 mm
2
Length ............................................................................................................................3 m
Diameter ............................................................................................................... 13.5 mm
Weight ................................................................................................................ 0.27 kg/m
Flame retardation ................................................................................................ IEC 332-1
Insulation ................................................................................................................... ETFE
Screen ................................................................................................................... Cu-braid
2.11.2
Processing Unit to MRU Junction Box cable
Type ........................................................................................... LAMAC, 4 x 2 x 0.5 mm
2
Maximum length .......................................................................................................100 m
Diameter .................................................................................................................. 10 mm
Summary of Contents for Seapath 320
Page 1: ...Seapath 320 Installation Manual ...
Page 20: ...Seapath 320 4 M300 62 rev 2 ...
Page 42: ...Seapath 320 26 M300 62 rev 2 ...
Page 98: ...Seapath 320 82 M300 62 rev 2 ...
Page 100: ...Seapath 320 84 M300 62 rev 2 5 1 Processing and HMI Units ...
Page 101: ...Installation Manual M300 62 rev 2 85 ...
Page 102: ...Seapath 320 86 M300 62 rev 2 5 2 Antenna bracket ...
Page 103: ...Installation Manual M300 62 rev 2 87 5 3 MRU and mounting bracket ...
Page 104: ...Seapath 320 88 M300 62 rev 2 ...
Page 105: ...Installation Manual M300 62 rev 2 89 5 4 MRU junction box ...
Page 107: ...Installation Manual M300 62 rev 2 91 5 6 6 U cabinet dimensions ...
Page 108: ...Seapath 320 92 M300 62 rev 2 ...
Page 126: ...Seapath 320 110 M300 62 rev 2 ...
Page 127: ...Installation Manual M300 62 rev 2 111 ...
Page 128: ...Seapath 320 112 M300 62 rev 2 ...
Page 129: ...Installation Manual M300 62 rev 2 113 ...
Page 130: ...Seapath 320 114 M300 62 rev 2 ...
Page 133: ...Installation Manual M300 62 rev 2 117 APPENDIX D COAX CABLE SPECIFICATION ...
Page 134: ...Seapath 320 118 M300 62 rev 2 ...
Page 135: ...Installation Manual M300 62 rev 2 119 APPENDIX E RG 214 SPECIFICATIONS ...
Page 136: ...Seapath 320 120 M300 62 rev 2 ...
Page 152: ...Seapath 320 136 M300 62 rev 2 ...