![Kongsberg cJoy OT Operator'S Manual Download Page 35](http://html1.mh-extra.com/html/kongsberg/cjoy-ot/cjoy-ot_operators-manual_1992577035.webp)
Status
The operational status of the position-reference system,
which can be
Calibrating
,
Online
,
Offline
or
Lost
. If the
position-reference system is in a monitoring state (operating but
not providing position-reference data) the status text is displayed
with the prefix
Mon
, e.g.
Mon Online
.
If the measurements are acceptable,
Calibrating
or
Online
are
displayed.
If the measurements are lost,
Offline
is displayed with red frame
around the circle. If the measurements are lost during calibration,
Lost
is displayed with red frame around the circle.
Weight
A blue horizontal bar that shows the weighting factor applied to
the measurements from the position-reference system during
the last second.
Because the system only has one position-reference system, its
Weight
will always be one (full bar) when the position-reference
system has an
Online
status.
If no new update is received from the position-reference system
during the previous second, the
Weight
for the system is set to
minimum (zero).
Standard deviation
A blue horizontal bar that shows the standard deviation of the
position measurements from the position-reference system.