![Kongsberg cJoy OT Operator'S Manual Download Page 104](http://html1.mh-extra.com/html/kongsberg/cjoy-ot/cjoy-ot_operators-manual_1992577104.webp)
Kongsberg cJoy OT
• If a high speed operation is selected the
Manual SPD
-
Use
field changes to green.
6
Close the Sensor Enable input dialog.
Disabling a manual speed value
To disable a manual speed value, proceed as follows:
1
Display the Sensor Enable input dialog for speed sensors.
2
Move the focus to the
Manual SPD
-
Enable
field and change the option to
Off
.
3
Press the
Enter
button.
• The manual speed value is disabled.
4
Close the Sensor Enable input dialog.
Position-reference system
Position information from the GPS position-reference system provides position
information as Latitude and Longitude in a geodesic coordinate system.
System datum
The controller PS always uses an internal geographic coordinate system, that uses
WGS84 as a “system datum”.
All position information from global reference systems which use a different datum are
converted internally to WGS84.
Reference origin
The position-reference system provides position measurements relative to a known
reference point. When the position-reference system is selected and accepted for use with
the system, it becomes the reference origin (the origin in the internal coordinate system).
Tests on position measurements
The system performs a series of tests on the position-reference system to check that its
position measurements are accurate enough for use.
The following online tests are performed:
• A
freeze test
rejects repeated measurements. If the variation in the measured position
is less than a system set limit over a given period of time, the position-reference
system is rejected.
• A
variance test
monitors the measurement variance and compares the variance value
with a calculated limit.