Kongsberg cJoy OT
•
-
— Message was reported by the controller PS and is now inactive (but not
acknowledged).
Time
Time when the message was first reported (
hour:minute:second
).
Pri.
The priority of the message:
•
A
— Alarm
•
W
— Warning
•
I
— Information
•
E
— Emergency
State
The event state for the message:
•
-
— Normal (indicates that the alarm or warning condition is no longer present)
•
On
— Active digital alarm
Text
Message text.
Info
Additional information. Up to three blocks of additional data may be included in
the message. The meaning of this additional data varies for each message.
For further information concerning the meaning of this additional information,
refer to the message explanations in Appendix A at the end of this manual.
Acknowledging messages
You can either acknowledge the message currently being displayed in the Message line
or all messages that are currently visible in the Message view.
Message line
To acknowledge the message currently shown in the Message line, proceed as follows:
1
If the audible signal horn is not sounding, press the
Silence/ack.
button once to
acknowledge the message.
• If the message has been reported as inactive, it is removed from the Message
line and replaced by the next most recent active Emergency, Alarm or Warning
message.
2
If the audible signal horn is sounding, press the
Silence/ack.
button twice with a
delay of at least 2 seconds between each press.
• The first press silences the audible signal.
• The second press acknowledges the message shown in the Message line.