S700 Safety Guide | 2 English
2.2.3 Prohibited Use
Other use than that described in chapter “Use as directed” is not intended and can lead to per-
sonnel injuries and equipment damage.
The use of the servo amplifier in the following environments is prohibited:
potentially explosive areas,
environments with corrosive and/or electrically conductive acids, alkaline solutions, oils,
vapors, dusts,
directly on non-grounded supply networks or on asymmetrically grounded supplies with a
voltage >240V,
ships or offshore applications.
Commissioning the servo amplifier is prohibited if the machine in which it was installed,
does not meet the requirements of the EC Machinery Directive,
does not comply with the EMC Directive or with the Low Voltage Directive,
does not comply with any national directives.
The control of holding brakes by the S700 alone may not be used in applications, where func-
tional safety is to be ensured with the brake.
2.2.4 Transport
Only by qualified personnel in the manufacturer’s original recyclable packaging
Avoid shocks
Temperature: –25 to +70°C, max. 20K/h rate of change, class 2K3 acc. to EN61800-2
Humidity: max. 95% relative humidity, no condensation, class 2K3 acc. to EN61800-2
If the packaging is damaged, check the unit for visible damage. In this case, inform the
shipper and the manufacturer.
The servo amplifiers contain electrostatically sensitive components which can be damaged
by incorrect handling. Discharge yourself before touching the servo amplifier. Avoid contact
with highly insulating materials (artificial fabrics, plastic films etc.). Place the servo amplifier
on a conductive surface.
2.2.5 Packaging
The S700 packaging consists of recyclable cardboard with inserts.
Dimensions S701...S712: (HxWxD) 125x415x350 mm
Dimensions S724:
(HxWxD) 155x415x350 mm
Dimensions S748/S772: (HxWxD) 390x600x400 mm
Labeling : nameplate outside at the box
2.2.6 Storage
Storage only in the manufacturer’s original recyclable packaging
Max. stacking height S701...S724: 8 cartons
Max. stacking height S748...S772: 3 cartons
Storage temperature: -25 to +55°C, max. rate of change 20K/h, class 1K4 acc. to
EN61800-2
Storage humidity: 5 ... 95% relative humidity, no condensation, class 1K3 acc. to
EN61800-2
Storage duration: Less than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo
amplifier. To do this, remove all electrical connections and apply single-phase 230V AC
for about 30 minutes to the terminals L1 / L2.
48
Kollmorgen | September 2015
Summary of Contents for S700 Series
Page 14: ...S700 Safety Guide 1 Deutsch 1 3 3 Antriebssystem mit S701 S724 14 Kollmorgen September 2015 ...
Page 15: ...1 3 4 Antriebssystem mit S748 S772 S700 Safety Guide 1 Deutsch Kollmorgen September 2015 15 ...
Page 40: ... S700 Safety Guide 1 Deutsch 40 Kollmorgen September 2015 ...
Page 52: ...S700 Safety Guide 2 English 2 3 3 Motion system with S701 S724 52 Kollmorgen September 2015 ...
Page 53: ...2 3 4 Motion system with S748 S772 S700 Safety Guide 2 English Kollmorgen September 2015 53 ...
Page 78: ... S700 Safety Guide 2 English 78 Kollmorgen September 2015 ...
Page 116: ... S700 Safety Guide 3 Français 116 Kollmorgen September 2015 ...
Page 154: ... S700 Safety Guide 4 Italiano 154 Kollmorgen September 2015 ...
Page 167: ...5 3 3 Приводная система с S701 S724 S700 Safety Guide 5 Русский Kollmorgen September 2015 167 ...
Page 168: ...S700 Safety Guide 5 Русский 5 3 4 Приводная система с S748 S772 168 Kollmorgen September 2015 ...
Page 194: ... S700 Safety Guide 5 Русский 194 Kollmorgen September 2015 ...
Page 214: ... S700 Safety Guide 6 Appendix 214 Kollmorgen September 2015 ...
Page 215: ... S700 Safety Guide Kollmorgen September 2015 215 ...