1.5 SPECIFICATIONS AND RATINGS
Table 1.4. Specifications
BDS5-1XX-(90-160 VAC L-L OUTPUT TO MOTOR)
DESCRIPTION
BDS5-103
BDS5-106
BDS5-110
BDS5-120
Main DC Bus
Minimum
Maximum
130 VDC
225 VDC
130 VDC
225 VDC
130 VDC
225 VDC
130 VDC
225 VDC
Unregulated Logic Bus
±
15-20 VDC
@0.25 AMPS
+8-12 VDC
@1.00 AMPS
±
15-20 VDC
@0.25 AMPS
+8-12 VDC
@1.00 AMPS
±
15-20 VDC
@0.25 AMPS
+8-12 VDC
@1.00 AMPS
±
15-20 VDC
@0.25 AMPS
+8-12 VDC
@1.00 AMPS
Output Current
(RMS/
∅
) Convection
Cooled (45
°
C AMB)
Continuous (RMS)
Peak (2.0 sec) (RMS)
3.0 AMPS
6.0 AMPS
6.0 AMPS
12.0 AMPS
10.0 AMPS
20.0 AMPS
Fan
Cooled
20.0 AMPS
40.0 AMPS
Output KVA
(@ 160 VDC Bus)
Continuous (45
°
C AMB)
Peak (2.0 sec) (RMS)
0.6 KVA
1.2 KVA
1.2 KVA
2.4 KVA
2.0 KVA
4.0 KVA
4.0 KVA
8.0 KVA
Internal Heat Dissipation
30 WATTS
40 WATTS
60 WATTS
110 WATTS
PWM Switching Frequency
10.0 kHz
10.0 kHz
10.0 kHz
10.0 kHz
Motor Current Ripple
Frequency
±
10%
20.0 kHz
20.0 kHz
20.0 kHz
20.0 kHz
Resolver Excitation Frequency
8.5 kHz
8.5 kHz
8.5 kHz
8.5 kHz
Form Factor RMS/AVG
≤
1.01
≤
1.01
≤
1.01
≤
1.01
Fan (115 VAC)
N/A
N/A
N/A
0.2 AMPS
Summary of Contents for BDS5
Page 2: ......
Page 3: ...BDS5 INSTALLATION AND SETUP MANUAL Old Number M93101 ISSUE 4 New Number MB5000H...
Page 4: ......
Page 8: ......
Page 10: ......
Page 18: ......
Page 20: ......
Page 62: ...CHAPTER 2 INSTALLATION BDS5 2 26...
Page 73: ...BDS5 CHAPTER 4 MAINTENANCE...
Page 74: ...CHAPTER 4 MAINTENANCE BDS5...
Page 78: ...CHAPTER 4 MAINTENANCE BDS5 4 4...
Page 86: ...APPENDIX A WARRANTY INFORMATION BDS5 A 2...
Page 88: ...APPENDIX B DRAWINGS BDS5 B 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 116: ......