Install the Plumbing (cont.)
Provide access at the back of the plumbing wall to make drain connections to the receptor.
Install the shower valving according to the manufacturer’s instructions. Do not install the trim at
this time.
4. Prepare the Module
CAUTION: Risk of property damage.
Make sure a watertight seal exists around the drain. If a
watertight seal on the drain is not obtained, water damage to the subfloor may occur.
Install the drain to the module according to the drain manufacturer’s instructions.
Layout and mark the location of the mixing valve, shower, and the bath spout holes on the back
surface of the module wall.
NOTE:
If the supply fittings have been located accurately during rough fitting, a pilot hole template can be
used for multiple installations. Make a pilot hole template of lightweight plywood. Use the pilot hole
template to mark fitting locations on the back side of the module.
Drill 1/4
″
(6 mm) pilot holes at the marked locations.
Clean the module to reduce the risk of surface damage.
Place a clean drop cloth or other similar material into the bottom of the module.
From the inside of the module (finished surface), use a hole saw of the correct diameter to carefully
drill the fitting holes.
Clean any debris from the module to reduce the risk of surface damage. Be careful not to scratch the
surface of the unit.
1030529-2-B
10
Kohler Co.
Spec Seq#: 102
31928
Summary of Contents for K-3363
Page 1: ...Spec Seq 72 S 1...
Page 15: ...Spec Seq 81 S 2...
Page 31: ...Spec Seq 90 WF 1...
Page 49: ......
Page 50: ...Spec Seq 94 MB 1...
Page 52: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 53: ...Spec Seq 96 189085...
Page 54: ...Spec Seq 96 189085...
Page 55: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 58: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 76: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 94: ...Spec Seq 100 SH 1...
Page 174: ...Spec Seq 112 SH 2...