3
Install Pedestal
Remove molding strips or tiles which could
prevent a flush mounting to the wall.
MOUNTING
PANEL
LOWER
BRACKET
CENTERLINE
PEDESTAL
ASSEMBLY
FLOOR ANCHOR
LOCATION
WALL ANCHOR
LOCATION
A
Measure and mark the centerline of the washfountain
on the wall and floor .
B
Before mounting the pedestal to the floor, make sure
the floor is level . If it is not level, be prepared to install
shims when positioning the pedestal in Step C .
C
With someone to assist you, move the pedestal
assembly to the wall using appropriate lifting
procedures, and align the locating notches on the
mounting panel with the centerline marked on the
wall . If the floor is not level, install shims under the
left and/or right pedestal .
D
Drill holes in the wall through the four 1/2" diameter
holes in the mounting panel and install four anchors
(supplied by installer) for
3
/8" bolts .
E
Secure the pedestal assembly to the wall anchors
using four
3
/8" bolts and washers (supplied by
installer) .
F
Drill holes in the floor through the two 1/2" diameter
holes in the lower bracket and install two anchors
(supplied by installer) for
3
/8" bolts .
G
After floor anchors are installed, secure the pedestal
assembly to the floor anchors using two
3
/8" bolts
and washers (supplied by installer) .
Summary of Contents for K-3363
Page 1: ...Spec Seq 72 S 1...
Page 15: ...Spec Seq 81 S 2...
Page 31: ...Spec Seq 90 WF 1...
Page 49: ......
Page 50: ...Spec Seq 94 MB 1...
Page 52: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 53: ...Spec Seq 96 189085...
Page 54: ...Spec Seq 96 189085...
Page 55: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 58: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 76: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 94: ...Spec Seq 100 SH 1...
Page 174: ...Spec Seq 112 SH 2...