Renewing MVP
™
Metering Valve
7
Step 1
Remove color coded index button
from handle with small, flathead screwdriver.
Step 2
Insert 3/32" allen wrench in handle
hole, loosen allen screw and remove handle.
Step 3
To adjust the flow cycle of the MVP
valve, turn the adjustment nut clockwise to
increase the duration of the flow cycle and
counter clockwise to decrease the flow cycle.
*After adjustment nut has been
repositioned, replace handle,
push down and test flow cycle.**
See page 6 for additional timing adjustment.
Step 4
If MVP cartridge is to be replaced,
TURN OFF WATER SUPPLY BEFORE
PROCEEDING
. Using a wrench, remove
actuator assembly.
Step 5
Grasp cartridge valve top with
needle-nose pliers, remove MVP cartridge
from valve body. Be careful not to bend pin.
Remove filter screen from inside of body with
finger tip.
Step 6
Place new filter, screen and MVP
cartridge in valve body.
Step 7 and 8
Replace cap sealing washer and actuator assembly. (Adjust flow cycle as
described in #3.) Do not over tighten cap.
* While the adjustment nut can be hand adjusted, you may have to start the
adjustment by using a wrench or pliers. It is important to grip the adjustment
nut loosely so as not to deform or damage the nut.
Step 9
Replace handle, tighten handle nut
with allen wrench and replace index button.
** To properly test the flow cycle, the
valve handle must be in place and
actuated.
Adjustment
Spec Seq#: 98
361769
Summary of Contents for K-3363
Page 1: ...Spec Seq 72 S 1...
Page 15: ...Spec Seq 81 S 2...
Page 31: ...Spec Seq 90 WF 1...
Page 49: ......
Page 50: ...Spec Seq 94 MB 1...
Page 52: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 53: ...Spec Seq 96 189085...
Page 54: ...Spec Seq 96 189085...
Page 55: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 58: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 76: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 94: ...Spec Seq 100 SH 1...
Page 174: ...Spec Seq 112 SH 2...