6
MVP
™
Metering Valve
665-PSHJKCP
- Push handle
665-505JKNF
- 3/32" hex socket wrench
665-309KJKNF
- Red
and blue index buttons
665-116JKNF
- Hex socket screw
665-015JKRBF
- Spring retainer
665-105JKNPF
- Stem
668-013JKNF
- Return spring
665-118JKNF
- Adjustment nut
665-190KJKNF
- Actuator
671-XJKNF
- Cartridge assembly
Cap assembly
“O” Ring
Retainer ring
665-011JKNF
- Cap sealing washer
Valve sleeve
667-107JKNF
- “O” Ring
Poppet/seat assembly
667-402JKNF
- Large filter
667-202JKNF
- Filter for use with non-dashpot bodies
Timing Adjustment on an MVP Metering Cartridge
1
With handle in place, purge cartridge of air by pushing completely down 4-8 times rapidly,
then check timing cycle.
2
Remove handle with a 3/32 allen wrench.
3
Use a standard pair of pliers (other tools may damage the adjustment nut) to change height
of adjustment nut by 1/4 turn only. Turn adjustment nut clockwise to increase time.
4
Replace handle and time flow. NOTE: TIMING MUST BE CHECKED WITH HANDLE IN PLACE
5
If more adjustment is needed, follow steps 3 and 4 until timing is right.
6
Attach handle and tighten screw. Press index button into handle opening.
Adjustment
Nut
▼
Index
button
▼
Set
screw
▼
Typical
Body
▼
with red and blue
index buttons
and set screw
Assembly
665-007JKNF
- (2) “E” ring retainers
Spec Seq#: 98
361769
Summary of Contents for K-3363
Page 1: ...Spec Seq 72 S 1...
Page 15: ...Spec Seq 81 S 2...
Page 31: ...Spec Seq 90 WF 1...
Page 49: ......
Page 50: ...Spec Seq 94 MB 1...
Page 52: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 53: ...Spec Seq 96 189085...
Page 54: ...Spec Seq 96 189085...
Page 55: ...5431 West 164th Street Brook Park Ohio 44142 Spec Seq 96 189085...
Page 58: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 76: ...Cartridge Maintenance Repair Guide Spec Seq 98 361769...
Page 94: ...Spec Seq 100 SH 1...
Page 174: ...Spec Seq 112 SH 2...