Item
Part number
Part name
Q'ty
Replacement interval
Hydraulic oil tank
PW52V01001R100
Return filter element kit
(STD, Breaker)
1
Replace at 50 hours for the
first time, then every 1000
hours
(Every 250 hours for breaker
specification)
(ZD11G11000)
(O-ring)
1
Hydraulic oil tank
PW50V00015F6
Suction strainer
1
Clean every 2000 hours
(ZD11G11500)
(O-ring)
1
Air breather
YN57V00002S010
Element
1
Replace every 1000 hours
Every 1000 hours
replacement is just a guideline.
If the machine is operated in
very dusty conditions, replace
the element earlier.
Air cleaner
PM11P00012S006
Element (Outer)
1
Replace every 6 times
cleaning or every 1 year
PW11P01038P1
Element (Inner)
1
Engine oil filter
129150-35153
Cartridge
1
Replace at 50 hours for the
first time,
then every 250 hours
Fuel filter
119802-55801
Cartridge
1
Replace every 500 hours
Water separator
119802-55730
Element
1
When required
24321-000650
(O-ring)
1
Radiator
PM05P00013S002
Radiator cap
1
Replace every 1000 hours
Bucket (STD)
PV69B00002P1
Side cutter (right)
1
When required
PV69B00003P1
Side cutter (left)
1
ZS13C16040
Bolt
6
ZN13C16013
Nut
6
YJ69B00002S001
Teeth
4
YJ69B00002S002
Locking pin
4
YJ69B00002S003
Rubber lock
4
4
4.4
MAINTENANCE PARTS
Replace parts, such as filters and elements, during the periodical maintenance or before the end of the
service life.
The machine can be used economically if the maintenance parts are changed properly and timely.
When you place an order of parts, confirm the parts number on the parts manual.
Filter and Element List
Parts enclosed in parenthesis ( ) are to be changed at the same time.
[
4. INSPECTION AND MAINTENANCE
]
4-9
Copyright © 2015 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2PX00051ZE03] [0731CsCshWbYs]