Figure 4-12: Alarms Screen
Table 4-4
Alarms Screen
Alarm Indication Result
Overstroke
High stroke rate caused by
external or internal leak
First a
WARNING
, and then a
PENDING
shutdown alarm will occur. If the
condition persists a shutdown will
occur.
Oil
High oil temperature, in excess
of 150
°
F (65
°
C)
Shutdown will occur 60 seconds after
detection.
Temp High
High booster water
temperature, in excess of 128
°
F (53
°
C)
Shutdown will occur 30 seconds after
detection.
B
oost
er
Press Low
Low water pressure from
booster pump, less than 30 psi
(2 bar)
Shutdown will occur 20 seconds after
detection.
Battery Low
Battery is low and needs to be
replaced
The battery will last approximately
seven days after the alarm occurs.
Inlet Low
Low inlet water pressure, less
than 30 psi (2 bar)
Shutdown will occur if condition
persists for 5 continuous seconds.
Water Press
ure
Outlet High
Excessively high outlet water
pressure, in excess of 64,000
psi (4,413 bar)
Available only when equipped with
optional pressure transducer. Does not
result in a shutdown.
Summary of Contents for STREAMLINE SL-V SRP 100
Page 23: ......
Page 25: ......
Page 174: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 5 Figure 12 1 SL V SRP 100 Intensifier Unit ...
Page 176: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 7 Figure 12 2 Intensifier Assembly ...
Page 184: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 15 Figure 12 7 High Pressure Piping ...
Page 188: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 19 Figure 12 9 Hydraulic Power Package ...
Page 190: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 21 Figure 12 10 Motor Pump Assembly ...
Page 192: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 23 Figure 12 11 Hydraulic Manifold Assembly ...
Page 194: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 25 Figure 12 12 Hydraulic Hose Connections ...
Page 196: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 27 Figure 12 13 Reservoir Assembly ...
Page 199: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 30 Figure 12 14 Bulkhead Pipe Assembly ...
Page 201: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 32 Figure 12 15 Cover Assembly ...
Page 205: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 36 Figure 12 17 Electrical Assembly 230 50 60 ...
Page 223: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 54 Figure 12 25 High Pressure Transducer ...
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......