![KMT STREAMLINE SL-V SRP 100 Operation And Maintenance Manual Download Page 261](http://html1.mh-extra.com/html/kmt/streamline-sl-v-srp-100/streamline-sl-v-srp-100_operation-and-maintenance-manual_1979679261.webp)
460 F (238 C) (Grade 220)
490 F (254 C) (Grade 320)
509 F (265 C) (Grade 460)
Flash Point (typical): 450 F (232 C) (Grade 32)
460 F (238 C) (Grade 46)
470 F (243 C) (Grade 68)
515 F (268 C) (Grade 100)
530 F (277 C) (Grade 150)
545 F (285 C) (Grade 220)
580 F (304 C) (Grade 320)
585 F (307 C) (Grade 460)
Method: COC
Autoignition: Not Available
Flammable limits in Air, % by Volume
LEL: Undetermined
UEL: Undetermined
Extinguishing Media
Water Spray, Foam, Dry Chemical, CO2.
Fire Fighting Instructions
Water or foam may cause frothing. Use water to keep fire-exposed
containers cool. Water may be used to flush spills away from
exposures.
Products of combustion may contain carbon monoxide, carbon dioxide,
and other toxic materials. Do not enter enclosed or confined space
without proper protective equipment including respiratory protection.
---------------------------------------------------------------------------
6. ACCIDENTAL RELEASE MEASURES
---------------------------------------------------------------------------
Safeguards (Personnel)
NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL) sections
before proceeding with clean-up. Use appropriate PERSONAL PROTECTIVE
EQUIPMENT during clean-up.
Remove source of heat, sparks, and flame.
Initial Containment
Dike spill. Prevent material from entering sewers, waterways, or
low areas.
Spill Clean Up
Recover free liquid for reuse or reclamation. Soak up with sawdust,
sand, oil dry or other absorbent material.
---------------------------------------------------------------------------
7. HANDLING AND STORAGE
---------------------------------------------------------------------------
Handling (Personnel)
Avoid breathing vapors or mist. Avoid contact with eyes. Avoid
prolonged or repeated contact with skin. Wash thoroughly after
handling. Wash contaminated clothing prior to reuse.
Handling (Physical Aspects)
Close container after each use. Do not pressurize, cut, weld, braze,
solder, grind, or drill on or near full or empty container. Empty
container retains residue (liquid and/or vapor) and may explode in
KMT 20418732
Summary of Contents for STREAMLINE SL-V SRP 100
Page 23: ......
Page 25: ......
Page 174: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 5 Figure 12 1 SL V SRP 100 Intensifier Unit ...
Page 176: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 7 Figure 12 2 Intensifier Assembly ...
Page 184: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 15 Figure 12 7 High Pressure Piping ...
Page 188: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 19 Figure 12 9 Hydraulic Power Package ...
Page 190: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 21 Figure 12 10 Motor Pump Assembly ...
Page 192: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 23 Figure 12 11 Hydraulic Manifold Assembly ...
Page 194: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 25 Figure 12 12 Hydraulic Hose Connections ...
Page 196: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 27 Figure 12 13 Reservoir Assembly ...
Page 199: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 30 Figure 12 14 Bulkhead Pipe Assembly ...
Page 201: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 32 Figure 12 15 Cover Assembly ...
Page 205: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 36 Figure 12 17 Electrical Assembly 230 50 60 ...
Page 223: ...Section 12 Parts List 20428786 2 2008 Rev 05 12 54 Figure 12 25 High Pressure Transducer ...
Page 224: ......
Page 225: ......
Page 226: ......
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ......
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......