Accessories/Spares
44
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210902001
Adjusting Tension on Pod Hook
Over a period of time it might be
necessary to increase the tension
on the pod hook found on the left
hand side of the pod due to mate-
rial fatigue. If two clicks are not
audible when connecting the pod
to the mask, it is time to service the
pod hook.
Begin by exposing the mounting screws by using your finger to gently
and slightly peel back a portion of the pod silicone skirt on the left side
to expose the three screws holding the hook to the pod frame. The hook
has four possible settings and arrives from our factory positioned at the
optimal setting.
If adjustment is needed remove the three screws and washers from inside
the pod frame and remove the pod hook cover found on the outside of the
assembly. With the hook accessible move the hook one slot closer to the
front of the pod (away from the mouth). Once it is secured into the new
slot reinstall the pod hook cover followed by the three screws to finalize
adjustment.
Accessories/Spares
Prescription Lenses
The following website is available to install prescription lenses onto your
M-48 mask:
Inlet Swivel P/N 305-017
The high flow swivel allows the regulator hose to
move freely and align with the mask without putting
stress on the hose coupling. It uses standard SCUBA
threads for incoming breathing air.