Post Dive Procedures/Checklist
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210902001
39
B
CAUTION
Failure to thoroughly rinse germicidal cleansing solu-
tion from the diving equipment may result in lung irrita-
tion and/or long-term degradation of rubber and silicone
components.
Sanitizing of the mask and pod is accomplished using one of the approved
germicidal cleansing solutions listed in the following “Germicidal Solutions
Manufacturers”. Follow the manufacturer’s mixing instructions and proce-
dures. It is important to thoroughly rinse with fresh water.
General guidelines are as follows: Wet or immerse all components to be
sanitized. Allow to stay in contact with solution for at least ten minutes
while lightly scrubbing over components with nylon toothbrush or clean
cloth to help remove mucous or saliva build up. If germicidal solution ap-
pears to be drying, apply more solution to keep components wet for full
ten minutes. After ten minutes, thoroughly rinse components under fresh
(potable) running water while brushing or rubbing components.
If equipment is not being used immediately, allow components to air dry
or pat dry with clean towel and reassemble.
Germicidal Solutions Manufacturers
1.
SaniZide Plus: P/N:
34805 (spray) or 34810 (gallon), Ready to use; do
not dilute. 1-800-456-7077
2.
MSA Confidence Plus:
P/N 10009971 (32 ounces) Mix one ounce of
concentrate with one gallon of fresh water.
3.
Steramine™
: Steramine Quaternary Sanitizing Tablets – 150 Sanitizer
Tablets per bottle 1 Tablet per gallon of water - Makes 150 gallons of
cleaning solution
Conservation and Storage
Ensure the mask and pod is thoroughly dry before storing. DO NOT STORE
with the pod attached to the mask. It is best for long term storage not to
have the pod attached to the mask.
Store the mask and pod at room temperature and out of direct sunlight.