Adjustments and Minor Repairs
42
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210902001
5. Install the water dump valve
body and valve back into the
pod skirt as one unit. Verify cor-
rect orientation of the valve and
seating into skirt tube.
NOTE
Valve orientation allows breathing gas and water to exit the pod
when installed correctly.
6. Insert purge sleeve into purge
tube, as shown (insert photo). Make
certain the direction of the sleeve is
correct and that it is pushed all the
way into the purge tube.
7. Insert these two parts together
into the tube of the pod skirt
until they are against the ex-
haust valve and water dump
valve body. Proper fit will show
no signs of bulging or dis-
placement on the tube with
alignment of the tube pointing
upwards.
NOTE
Step 8 cannot be completed until the Kirby Morgan Balanced
SCUBA Regulator is installed into the pod. See “Mounting Open