Post Dive Procedures/Checklist
40
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210902001
B
WARNING
When purchasing spare parts, always insist on Kirby
Morgan Genuine Parts. Although other parts may look
the same, they may not be manufactured to the same
standards of quality. Improperly manufactured parts can
cause accidents that can lead to injury or death.
Scheduled Maintenance
This user guide provides properly trained personnel with the guidance and
technical information needed to perform normal scheduled maintenance
and adjustments as described herein. Repairs and overhauls must be com-
pleted by M-48 SuperMask
®
authorized trained technicians.
NOTE
Read and understand each section before attempting the pro-
cedures found in the tables found in the user guide. Refer to the
accompanying figures for location of callouts included in these
maintenance steps. Also refer to the parts information included
in “Exploded View Drawing of the M-48 SuperMask® (No Pod)”
on page 51.
NOTE
Before scheduled maintenance is performed, all components
should be thoroughly cleaned in accordance with the procedures
found in “Cleaning Procedures” on page 37.
Disassembly Guidelines
Routine cleaning and maintenance is the best way to ensure long equip-
ment life and optimum performance. The following outlines scheduled
maintenance procedures for the M-48 SuperMask
®
.