30
PWX
Output Operations
The output turns on and off each time you press OUTPUT. When output is on, the OUTPUT
LED in the display area lights. When the output is off, the OUTPUT LED in the display area
turns off.
When the output is on, output is generated at the present set values.
If you change the settings while the output is on, the changes are applied immediately to the
output. If the output is off, the setting display will appear (the SET key lights) as soon as you
change the settings. Then, you can press OUTPUT to output using the new settings.
p. 48 , p. 71
You can use external control to turn the output on and off.
You can use the CONFIG settings to set the output-on startup state (CF12: prioritize CC or
CV).
Output on or off when the PWX series turns on
In the factory default settings, output is off when the PWX series turns on. Using a CONFIG
parameter (CF02:Forc), you can set the PWX series so that output is turned on at power on.
If you set the PWX series so that output is turned on at power on, be sure to check the OVP
trip point setting before you turn the PWX series off.
See
Lit
Output on
See
See
CAUTION
If you change the load, it may be damaged if the PWX series’s OVP and OCP settings are
not correct.
Summary of Contents for PWX1500H
Page 10: ...10 PWX This page is intentionally blank...
Page 26: ...26 PWX This page is intentionally blank...
Page 88: ...88 PWX This page is intentionally blank...
Page 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 92: ...92 PWX This page is intentionally blank...
Page 120: ...120 PWX This page is intentionally blank...
Page 121: ...Appendix A Options B Troubleshooting...