PWX
29
Panel Operations
Basic Functions
2
Overvoltage protection and overcurrent protection setting display
Press OCP•OVP to light its LED and display the present overcurrent protection and overvolt-
age protection settings.
System configuration setting display
Press CONFIG to light its LED and display the present system configuration settings.
Panel Operations
Measured value display, setting display, and set OVP/OCP display
Turn the VOLTAGE knob to change the voltage. Turn the CURRENT knob to change the cur-
rent.
Press SET to switch to the setting display, and then change the output voltage and output
current while you view their actual settings.
You cannot set the output voltage to a value that is 95% of the OVP trip point or higher. You
cannot set the output current to a value that is 95% of the OCP trip point or higher.
The displayed current or voltage may not change even if you turn the CURRENT or VOLT-
AGE knob. In this situation, the values are being changed at a finer resolution that which is
being displayed. The display will change when the amount that you change the value by
reaches the smallest display digit of the set voltage or current.
Fine adjustment
You can change the resolution of the VOLTAGE and CURRENT knobs.
Hold down SHIFT while you turn the VOLTAGE knob or CURRENT knob to make small
changes to the value.
Lit
Lit
Decrease
Increase
Increase
Decrease
See
Memo
When you set a value, it is
convenient to first use
normal resolution to set
the value roughly and
then switch to fine
resolution to set it
precisely.
Summary of Contents for PWX1500H
Page 10: ...10 PWX This page is intentionally blank...
Page 26: ...26 PWX This page is intentionally blank...
Page 88: ...88 PWX This page is intentionally blank...
Page 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 92: ...92 PWX This page is intentionally blank...
Page 120: ...120 PWX This page is intentionally blank...
Page 121: ...Appendix A Options B Troubleshooting...