44
PWX
CONFIG Settings
CF01 to CF36, CF41 to CF52 Specifying the CONFIG settings
Excluding resets the panel settings (CF00) and Resets or applies the LAN interface
settings (CF40)
1
Press CONFIG.
The CONFIG key lights, and the SET key blinks. The ammeter displays the parameter
number—CF00
. The voltmeter displays the corresponding setting—
rST
.
2
Press CONFIG or turn the CURRENT knob to select the number of the
parameter that you want to set.
When you press CONFIG, the PWX series switches between the parameter numbers
in the following order.
CF00
→
CF20
→
CF30
→
CF40
→
CF50
→
measured value display
When you turn the CURRENT knob, the PWX series switches between the parameter
numbers. The parameter numbers that are displayed are those within the ranges
defined by the parameter numbers that pressing the CONFIG key switches between.
3
Turn the VOLTAGE knob to change the value of the parameter.
4
To specify or display other parameters, repeat step2 and step3 .
To stop specifying CONFIG settings, proceed to step5 .
5
Continue pressing CONFIG until the measured value display appears.
Alternatively, press OUTPUT or PWR DSPL. If you are configuring a
slave unit, press CONFIG or PWR DSPL.
Some CONFIG parameters will be applied immediately after you set them, some will
be applied after you restart the PWX series, and some will be applied after you exe-
cute CF40 “APPL
”.
CF00/ CF40 Specifying the CONFIG settings
Resetting the panel settings (CF00)
Resetting or applying the LAN interface settings (CF40)
1
Press CONFIG once (for CF00) or four times (for CF40).
The CONFIG key lights and the SET key blinks.
If you pressed CONFIG once, the ammeter displays the parameter number—
CF00
. The voltmeter displays the corresponding setting—rST
.
If you pressed CONFIG four times, the ammeter displays the parameter number—
CF40
. The voltmeter displays the corresponding setting—Lci
/
dEF
/ APPL
.
2
Press SET, which is blinking.
The CONFIG key lights, and the SET key, the parameter number displayed on the
ammeter, and the setting displayed on the voltmeter all blink.
Memo
Press CONFIG or turn the
CURRENT knob to switch
between the parameter
numbers. These two
methods switch between
the parameter numbers
differently.
See
Lit
Blinking
Blinking
Blinking
Example of “LCi” displayed for CF40
Summary of Contents for PWX1500H
Page 10: ...10 PWX This page is intentionally blank...
Page 26: ...26 PWX This page is intentionally blank...
Page 88: ...88 PWX This page is intentionally blank...
Page 89: ...Maintenance This chapter explains how to perform cali bration DELETE...
Page 92: ...92 PWX This page is intentionally blank...
Page 120: ...120 PWX This page is intentionally blank...
Page 121: ...Appendix A Options B Troubleshooting...