GLOBal Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
GLOB:CURR
Sets the current of all the channels in the same multichannel domain.
Insert a wait of at least 200 ms after sending the GLOB:CURR command.
Command
GLOBal:CURRent[:LEVel][:IMMediate][:AMPLitude] <numeric>
Parameter
Value: 0 % to 105 % of the rated output current (the default value is MAXimum)
A SCPI error (-222, “Data out of range”) occurs if outside the range.
Unit: A
Rated output current
PWR401L
40 A
PWR801L
80 A
PWR1201L
120 A
PWR401ML
20 A
PWR801ML
40 A
PWR1201ML 60 A
PWR401MH
5 A
PWR801MH
10 A
PWR1201MH 15 A
PWR401H
1.85 A
PWR801H
3.70 A
PWR1201H
5.55 A
Settings are reset to default when the GLOB:*RST command is sent.
(Example)
GROB:CURR 2.5
GLOB:INIT:PROG
Starts the sequence trigger function of all the channels in the same multichannel
domain.
When the trigger source is set to IMM, the sequence is executed immediately.
When the trigger source is set to BUS, the PRW01 waits for a software trigger, and
then executes the sequence.
This command cannot be executed simultaneously with the TRANsient subsystem.
This command is not valid when the output is on.
Insert a wait of at least 200 ms after sending the GLOB:INIT:PROG command.
Command
GLOBal:INITiate[:IMMediate]:PROGram
Related Command
TRIG:PROG:SOUR