OUTPut Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
OUTP:DEL:ON
Sets the output-on delay.
Command
OUTPut:DELay:ON <numeric>
OUTPut:DELay:ON?
Parameter
Value:
0
No delay (default)
0.5 to 99.9
A SCPI error (-222, “Data out of range”) occurs if outside the range.
Unit:
S
Settings are reset to default when the *RST command is sent.
(Example)
OUTP:DEL:ON 1.2
Response
Returns the output-on delay setting in NR3 format in response to OUTP:DEL:ON?.
OUTP:DEL:OFF
Sets the output-off delay.
Command
OUTPut:DELay:OFF <numeric>
OUTPut:DELay:OFF?
Parameter
Value:
0
No delay (default)
0.5 to 99.9
A SCPI error (-222, “Data out of range”) occurs if outside the range.
Unit:
S
Settings are reset to default when the *RST command is sent.
(Example)
OUTP:DEL:OFF 1.2
Response
Returns the output-off delay setting in NR3 format in response to OUTP:DEL:OFF?.