[SOURce:]VOLTage Command
KIKUSUI Electronics Corp.
PWR-01 Interface Manual
[SOURce:]RESistance Command
RES
Sets the internal resistance.
If the variable internal resistance feature (factory options) is in use, this command
is valid.
If you are not using the variable internal resistance feature, set this to 0.
Setting the slave unit during master-slave parallel operation is invalid.
Command
[SOURce:]RESistance <numeric>
[SOURce:]RESistance?
Parameter
Value:
L/ ML type
0 to rated output voltage/ rated output current
MH/ H type 0 to rated output voltage/ rated output current x 0.75
(0 by default)
A SCPI error (-222, “Data out of range”) occurs if outside the range.
Unit:
OHM
Settings are reset to default when the *RST command is sent.
(Example)
RES 0.16
Response
Returns the internal resistance setting in NR3 format in response to RES?.
[SOURce:]VOLTage Command
VOLT
Sets the voltage.
When the PWR-01 is set so that constant voltage is controlled externally (VOLT:EX-
T:SOUR VOLT), settings performed by this command are invalid.
This command is invalid while a sequence is running.
Command
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <numeric>
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]?
Parameter
Value: 0 % to 105 % of the rated output voltage (MAXimum by default)
A SCPI error (-222, “Data out of range”) occurs if outside the range.
Unit: V
Rated output voltage
PWR401L
40 V
PWR801L
40 V
PWR1201L
40 V
PWR401ML
80 A
PWR801ML
80 V
PWR1201ML 80 V
PWR401MH
240 V
PWR801MH
240 V
PWR1201MH 240 V
PWR401H
650 V
PWR801H
650 V
PWR1201H
650 V
Settings are reset to default when the *RST command is sent.
VOLT 120
Response
Returns the voltage setting in NR3 format in response to VOLT?.