1
7. Turn on the OUTPUT switch of the master unit.
"CV" lights up on the control panel of the master unit, indicating
that the unit is in constant voltage operation mode.
The same output voltage and current displayed on the master unit
are also displayed on each slave unit. This means that the total
voltage of all the units is applied to the load.
Finishing the master-slave-control series operation
• To
fi
nish master-slave-control series operation,
always follow the procedure below. If the POWER
switch of the master unit is turned off while series
operations are still being carried out, the slave units
may malfunction.
1. Turn off the OUTPUT switch of the master unit.
2. Turn off the OUTPUT switch of each slave unit.
3. Turn off the POWER switch of each slave unit.
4. Turn off the POWER switch of the master unit.