1
Getting Started
Product at a Glance
20
E3632A User’s Guide
Voltage and current limit settings
You can set the voltage and current limit values from the
front panel using the following method.
Figure 1-3
Voltage and current limit settings
1
Select the desired range using the range selection keys
after turning on the power supply.
2
Press
to show the limit values on the
display.
3
Move the blinking digit to the appropriate position using
the resolution selection keys and change the blinking digit
value to the desired voltage limit by turning the control
knob. If the display limit times out, press
again.
4
Set the knob to current control mode using the
voltage/current adjust selection key.
5
Move the blinking digit to the appropriate position using
the resolution selection keys and change the blinking digit
value to the desired current limit by turning the control
knob.
6
Press
to enable the output. After about
five seconds, the display will go to output monitoring
mode automatically to display the voltage and current at
the output or the display will go to output monitoring
mode immediately by pressing
again.
Display Limit
Display Limit
Output On/Off
Display Limit
N O T E
All the front panel keys and controls can be disabled with the remote
interface commands. The power supply must be in the Local mode for the
front panel keys and controls to function.
Summary of Contents for E3632A
Page 1: ...Keysight E3632A DC Power Supply User s Guide ...
Page 2: ......
Page 3: ......
Page 12: ...X E3632A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 20: ...XVIII E3632A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Page 22: ...XX E3632A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...