OUTPut?
This query returns the output state of the power supply. The
returned value is
0
(OFF) or
1
(ON).
OUTPut:RELay {OFF|ON}
This command sets the state of two TTL signals on the
RS- 232 connector. These signals are intended for use with
an external relay and relay driver. The TTL output is
available on the RS- 232 connector pin 1 and pin 9. When
the
OUTPut:RELay
state is ON, the TTL output of pin 1 is
high (4.5 V) and pin 9 is low (0.5 V). The levels are reversed
when the
OUTPut:RELay
state is OFF. At
*RST
, the
OUTPut:RELay
state is OFF.
TTL output of pin 1 or pin 9 of the RS- 232 connector is
available only after installing two jumpers inside the power
supply. Refer to the
Service Guide
for more information.
OUTPut:RELay?
This command returns the state of the TTL relay logic
signals. See also
OUTP:REL
command.
SYSTem:BEEPer
Issue a single beep immediately.
N O T E
Do not use the RS-232 interface if you have configured the power supply to
output relay control signals. Internal components on the RS-232 circuitry
may be damaged.