background image

Keysight ZA0060A 

Custom IoT Device 

Functional Test Solution

 

Quick Start 

Guide

Summary of Contents for ZA0060A

Page 1: ...Keysight ZA0060A Custom IoT Device Functional Test Solution Quick Start Guide...

Page 2: ...r 2 Relinquish to or otherwise provide the govern ment rights in excess of these rights customarily provided to the public to use modify reproduce release per form display or disclose commercial compu...

Page 3: ...afe operation of the instrument Direct current DC Alternating current AC Caution risk of electric shock Caution risk of danger refer to this manual for specific Warning or Caution information Standby...

Page 4: ...er Verify that all safety precautions are taken Make all connections to the unit before applying power and select the appropriate power line voltage on the fuse module Ground the Instrument This produ...

Page 5: ...unauthorized modification to the product Return the product to a Keysight Sales and Service Office for service and repair to ensure that safety features are maintained In Case of Damage Instruments th...

Page 6: ...low condensation The table below shows the general environmental requirements for this instrument Environmental condition Requirement Temperature Operating condition 0 to 40 C Storage condition 40 to...

Page 7: ...gnetic Compatibility EMC regulations Safety compliance IEC 61010 1 2010 EN 61010 1 2010 IEC 61010 2 030 2010 EN61010 2 030 2010 Canada CAN CSA C22 2 No 61010 1 12 CAN CSA C22 2 No 61010 2 030 12 USA A...

Page 8: ...ions under the terms of the Radio Communication Act of 1992 ICES NMB 001 indicates that this ISM device complies with the Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB 001 du Canada T...

Page 9: ...this electrical or electronic product in domestic household waste Product category With reference to the equipment types in the WEEE directive Annex 1 this instrument is classified as a Monitoring and...

Page 10: ...ort To contact Keysight for sales and technical support refer to the support links on the following Keysight websites www keysight com find X8711A product specific information and support software and...

Page 11: ...rements 14 Software requirements 14 Hardware Configuration 15 Software Installation 17 TAP and Measurement Suite License Redemption 19 TAP and Measurement Suite License Installation 22 Node Locked Lic...

Page 12: ...isted 55 Keysight 34999B Not Detected in Device Manager 56 Keysight 34972A Not Detected in Keysight IO Library 56 Incorrect Slot for 34999B 56 34972A Connectivity Error 57 Test Plan Execution Error Me...

Page 13: ...into a shield box and running the software test plans to get the transmitter and receiver test results in seconds With ZA0060A you can now extend your test coverage for Bluetooth 5 and Zigbee 3 0 on...

Page 14: ...ve Keysight IO Libraries Suite version 18 0 or above Keysight Test Automation Platform TAP Software version 8 7 KS8400A TAP Developer s System or KS8000A TAP Deployment System Keysight 34999 Utility s...

Page 15: ...insert them into 1 slot 200 Ensure that you have tightened the L locking bracket with a screw on 6 Chassis Ground Screw 2 Connect the following cables with reference to the image below i RF cable fro...

Page 16: ...4972A Allow 15 seconds after powering on the 34972A for your PC to detect the instrument and its VISA address NOTE The input power measurement range of the ZA0060A low power WLAN option is from 4 to 4...

Page 17: ...are packages for the ZA0060A solution Download the latest Install wizard to access the new releases of the software packages 1 Download and install the X8711A ZA0060A Install wizard from www keysight...

Page 18: ...suites and software prerequisites in the Action column as shown below The 34999 Utility application is a compulsory software and will be selected by default when it is not installed in your PC 5 When...

Page 19: ...Manager capability 3 Click You can add a new certificate 4 Enter the Order Number and Certificate Number from your Keysight License Entitlement Certificate Click Continue 5 Review the summary of the...

Page 20: ...click Add a new host and enter the Host ID from the Keysight License Manager b For floating licenses click Add a new MAC Address host and enter the MAC address of your server c For USB portable licens...

Page 21: ...page below Click Yes to assign more license s to other hosts Otherwise click No and followed by Continue 10 Enter your email address and click Submit You should receive an email shortly NOTE For more...

Page 22: ...t with the lic extension to your PC 2 Launch Keysight License Manager 3 Perform the following steps with reference to the image below a Click the tools icon 1 followed by Install License File 2 b Loca...

Page 23: ...omplete installation 3 Download and install the FLEXID10 USB Dongle Driver package at www keysight com find licensingusbdriver a Extract the files to a convenient location b Execute the Setup64 exe on...

Page 24: ...art Guide 24 5 Launch Keysight License Manager 6 from your computer s Start menu Click the Add remove a license to your local machine 6 Click the Add a license to this floating license server to be us...

Page 25: ...25 7 Click Browse and browse to the location of the license File Click Next When you are prompted to run a service in a pop up window click Yes 8 You should see the image below the licensing actions w...

Page 26: ...and the details of the license You may need to click Refresh if it is not listed In this example KS83301B is successfully installed in the KLM 6 10 Go to the Windows menu search for Edit the system e...

Page 27: ...one if it is not listed in either User or System variables 12 Click New to create the LM_LICENSE_FILE variable and enter the information as shown below Click OK and you may close all the windows rela...

Page 28: ...led measurement suite Based on the example below you can now load the test plans from the BLE measurement suite in TAP with the KS83301B license installed 14 Repeat these steps on each machine on whic...

Page 29: ...Result Listener plug ins on the left tab Click to view more options other than Log and Simple CSV c For Log configure the File Path settings and set the Filter Options according to your preference d...

Page 30: ...e channel set by the DUT for transmission MHz PAN ID Hex Decimal Enter the unique PAN ID of the Zigbee network to allow communication between the coordinator and router You can use the PAN ID created...

Page 31: ...module as a Zigbee coordinator or router The selection here will load the appropriate firmware file in the RF module Initialize Zigbee Signaling This test step must be a child step of Initialize Zigb...

Page 32: ...etwork with router or end device depending on the role of 34999B module as coordinator or router Step Settings Timeout Set the time seconds to wait for the link to be established between 34999B and DU...

Page 33: ...e will interpolate the offsets of the selected channel 8 using the values from channel 6 and 11 PER limit Set the upper limit of PER Results that exceed this PER limit will be reported as Fail Packet...

Page 34: ...50 000 milliseconds For example setting the Window Time at 50 seconds would mean that you will need to reset the DUT within 50 seconds to disconnect the DUT from any network and resume beaconing befor...

Page 35: ...reated a test plan that suits your testing requirement turn on your DUT and place it in the shield box Click Run to start the test plan 6 Observe the Log panel as it will display a Passed or Failed me...

Page 36: ...is set at 55 dBm This setting will activate the uplink RSSI matching mechanism to match the set UplinkRssiTarget Active Scan time Set delay time between each active scan from 100 milliseconds to 10 se...

Page 37: ...mum to determine the advertising interval Use User Entry mode when there is a known range of advertising interval This step only measures the advertising interval of the DUT without assessing it as Pa...

Page 38: ...000 milliseconds ADC Noise Floor Set the ADC noise floor for advertising channel Tx power detection and measurement Any RF events that occur above the set noise floor will trigger power measurement D...

Page 39: ...evice is selected in this step Step Settings System Offset Set path loss to DUT DL Power dBm Select the value from the drop down list The software will calculate the output power based on this value a...

Page 40: ...test Early Fail Count Set the maximum number of consecutive failed packet allowed before reporting error Scan Delay from Measure Advertising Interval Step There are two options for this setting Select...

Page 41: ...efault settings are used the radio will scan the devices based on the first connection method listed UUID handle until it finds a method that reports Pass consecutively for three response iterations C...

Page 42: ...advertising for a period of time after it is disconnected from the master tester or do not allow subsequence connections made continuously mainly for security purpose avoid device hacking If the BLE...

Page 43: ...as described under Connect Request for Bluetooth 5 test step Step size Select a sweep step size of 1 or 0 5 dB Direction A high to low direction will sweep the power levels from maximum to minimum Th...

Page 44: ...produces a Pass verdict Mid point Bi directional Search for the PER sensitivity level using a combination of binary and linear sensitivity searches From the first break point of the binary search it w...

Page 45: ...Power List dBm Enter the values in this order minimum output power step size maximum output power For example when the step size is set as 5 the test step will cycle in 5 dBm increment from 100 to 95...

Page 46: ...handle Reads the UUID handle decimal or hexadecimal of the characteristic set of your DUT Select the Custom option in the drop down list to enter a custom handle value Ensure that the VISA address of...

Page 47: ...in the shield box Click Run to start the test plan 6 Observe the Log panel as it will display a Passed or Failed message when the test completes 7 Once the test is complete you can view the results at...

Page 48: ...N connection with a maximum length of 32 characters Security Type Select Open WEP or WPA2 option For the WEP and WPA2 option you will need to enter the security key You can also choose to view the sec...

Page 49: ...time based or manual option The time based option will introduce a Time Out setting where you will need to enter the time in seconds Execution Mode Select the CLI or GUI mode In GUI mode you will see...

Page 50: ...n the System Offsets the software will interpolate the offsets using the two nearest channels For example the software will interpolate the offsets of the selected channel 8 using the values from chan...

Page 51: ...nnel View the description for System Offset in the Signaling PER test step Lower and Upper Trigger Power Level Set the upper and lower trigger such that the DUT Tx Power will fall within the range Mea...

Page 52: ...tment Receiver Sensitivity Search comprises of Binary Sensitivity Search Linear Sensitivity Search and Mid point Sensitivity Search Go NoGo Test WLAN Access Point Device Discovery This test plan funct...

Page 53: ...is not causing the failure No Valid Radio Options License Found Hardware option error will appear when the respective radio options are not enabled and you will need to purchase certain licenses acco...

Page 54: ...out on BLE Radio COM port data read The Port COM Port number does not exist Here are a few tips that you can try Verify the correct COM port setting of the 34999B instrument Follow the steps in COM Po...

Page 55: ...sight 34999 Utility software Connect and disconnect the cables and observe if the USB Test and Measurement Device 34999B is listed in Ports COM LPT Reboot your PC when it is still unable to detect the...

Page 56: ...ossible error messages when the connection of the Keysight 34999B to the 34972A is inactive Inner Exception Could Not Connect to Keysight 34999B with Resource Name VISA Address of 34972A Inner Excepti...

Page 57: ...Once you have purchased the license s you will receive an entitlement certificate via email Follow the instructions in the email to redeem the license 34972A Front Panel Annunciator Turn On Refer to...

Page 58: ...ect to change without notice Always refer to the English version at the Keysight website for the latest revision Keysight Technologies 2020 Edition 2 March 2020 Printed in Malaysia ZA0060 90000 ZA0060...

Reviews: