Carrying out emptying
41 / 61
2019/11
010-917_SON_EN
5.2
Emptying system type D
C
D
E F
Workflow diagram for emptying cycle (Euro standard 1825)
Setting
in the menu
A
Emptying period
A1 Automatic operation (cleaning and shredding, part filling)
A2 Filling of the system tank (started by the user)
B
Emptying vehicle is pumping off
1
Pump in operation (cleaning and shredding)
3.1.1
2
Valve part fill (hot water supply*)
3.1.2
3
Valve fill (cold water supply, started by the user)
3.1.3
4
Time delay before pump(s) (1) start(s), so that the level drops by approx. 10 cm
3.1.4
* recommended
Carrying out emptying
• Switch the control unit on.
• Connect the extraction hose of the emptying vehicle to the direct disposal pipe.
•
Start
automatic operation,
after the time delay has expired
1
see above<4>, the pump is switched on
automatically for the time corresponding tot eh nominal size
1
.
•
Then the function part fill
1
is activated.
If the system tank is not filled with water again after emptying (upper edge outlet assembly lower section),
greases and suspended matter can flow freely into the sewage system.
• When the system tank is completely empty, remove the extraction hose from the emptying vehicle.
• Activate the function
Start filling?
by pressing OK, the system tank is filled completely with cold water.
• Then acknowledge the message
Filling successfully completed!
by pressing OK, and switch the control unit
off.
1) Period can be set in the menu (see table above Abb. [38])
A
B
1
3
A2
4
2
A1
Abb. [38]
5.3
Emptying system type E
C D
E
F
Workflow diagram for emptying cycle (Euro standard 1825)
A
Emptying period
A1 Manual operation (pump operating times)
A2 Filling of the system tank (by the user)
B
Emptying vehicle connected
C
Pump in operation
C1
Pump on
(pumping off, to the emptying vehicle)
C2
Pump on
(cleaning and shredding)
D
Valve switchover by user
D1 Switching position
Pump off
D2 Switching position
Cleaning and shredding
E
Hot water* supply (
part fill, E
switched on and off by the user)
F
Cold water supply (
fill, E
switched on and off by the user)
G
Emptying times (from page 45)
* recommended
A
B
C
D
E
F
C1
C2
D1
D2
A1
A2
G
1
2
3
4
5 6
7
8 9
10 11
12
13
Abb. [39]