Carrying out emptying
39 / 61
2019/11
010-917_SON_EN
5.1
Emptying system type C
C
D E F
Workflow diagram for emptying cycle (Euro standard 1825)
A
Emptying period
B
Emptying vehicle is pumping off
1
Pump(s) in operation (cleaning and shredding)
2
Hot water* supply
3
Cold water supply
4
Time required for the level to drop approx. 10 cm
* recommended
Carrying out emptying
•
Connect the extraction hose of the emptying vehicle to the direct disposal pipe and start pumping off.
• When the level has dropped by approx. 10 cm, switch the pump(s) on (cleaning and shredding).
• When the system tank is about 1 third empty, open the hot water supply.
• When the system tank is almost empty, stop the pump(s) and the hot water supply.
If the system tank is not filled with water again after emptying (upper edge outlet assembly lower section),
greases and suspended matter can flow freely into the sewage system.
•
When the system tank is completely empty, remove the extraction hose from the emptying vehicle and fill the
system tank completely with cold water.
•
Close the shut-off valve of the refill inlet once the system has been filled.
A
B
1
3
4
2