64 / 264
Installation
03/2015
Control unit and pump(s) with 230 V operating voltage
• Connect pump(s) to the plug-type connections <b and c>.
3.8.2 Connecting potential-free contacts
(Option)
Signal
Connection
Description
Fault
<24> (Fig. [20])
Switch position OFF in the case of a fault message (see chapter 7)
and shut-down control unit.
Warning
<25> (Fig. [20])
Switch position ON for signal ALARM LEVEL exceeded
3.8.3 Connecting the level sensor and pressure sensors
• Establish connections for the level sensor as follows.
Connection (Fig. [20])
Colour coding cable
Alarm sensor
d
red
Pressure sensor
e
-
Optical probe for backwater flap
f
none
Motor for backwater flap
g
dark grey
• Route all cables for the electric components and the pressure sensor line safely. Recommendation:
attachment to the cable pipe clamps that can be mounted on the wall of the inspection chamber.
Route the pressure hose (connection e) of the immersion pipe (pressure sensor) in such a way that it always
runs at a rising gradient. This prevents condensation forming which could lead to malfunctions.
b c
Abb. [37]
Summary of Contents for 010-694
Page 42: ...42 264 Leistungserkl rung DOP 03 2015 9 Leistungserkl rung DOP...
Page 43: ...Leistungserkl rung DOP 43 264 03 2015...
Page 86: ...86 264 Declaration of conformity 03 2015 9 Declaration of conformity...
Page 87: ...Declaration of conformity 87 264 03 2015...
Page 129: ...D claration de conformit 129 264 03 2015 9 D claration de conformit...
Page 130: ...130 264 03 2015...
Page 131: ...131 264 03 2015...
Page 173: ...Dichiarazione di conformit 173 264 03 2015 9 Dichiarazione di conformit...
Page 174: ...174 264 Dichiarazione di conformit 03 2015...
Page 175: ...175 264 03 2015...
Page 218: ...218 264 Conformiteitsverklaring 03 2015 9 Conformiteitsverklaring...
Page 219: ...Conformiteitsverklaring 219 44 03 2015...
Page 261: ...Dane techniczne 261 264 03 2015...
Page 262: ...262 264 Deklaracja zgodno ci 03 2015 9 Deklaracja zgodno ci...