6482-901-01 Rev. A / August 2012
Return to
16-51
Model 6482 Dual-Channel Picoammeter / Voltage Source Reference Manual
Section 16: SCPI Command Reference
Read condition registers
CONDition?
:STATus:MEASurement:CONDition?Read Measurement Condition
:STATus:QUEStionable:CONDition?Read Questionable Register
:STATus:OPERation:CONDition?Read Operation Condition
Description
These query commands are used to read the contents of the condition registers.
Select default conditions
PRESet
:STATus:PRESet Return
registers to default conditions
Description
When this command is sent, the following SCPI event registers are cleared to
zero (0):
1. Operation Event Enable Register.
2. Event Enable Register.
3. Measurement Event Enable Register.
NOTE
The Standard Event Register is not affected by this command.
Error queue
[:NEXT]?
:STATus:QUEue[:NEXT]?
Read error queue
Description
As error and status messages occur, they are placed into the error queue. This
query command is used to read those messages. See
messages.
NOTE
The :STATus:QUEue[:NEXT]? query command performs the same function as the
:SYSTem:ERRor? query command. See
“SYSTem subsystem,” page Section 16-52.
CLEar
:STATus:QUEue:CLEar
Clear error queue
Description
This action command is used to clear the error queue of messages.
ENABle <list>
:STATus:QUEue:ENABle <list> Enable messages for error queue
Parameters
<list> = (numlist)
where numlist is a specified list of messages that you wish to enable for the Error.
Query
:ENABle?
Query list of enabled messages
Description
On power-up, all error messages are enabled and will go into the error queue as
they occur. Status messages are not enabled and will not go into the queue. This
command is used to specify which messages you want enabled. Messages not
specified will be disabled and prevented from entering the queue.
Summary of Contents for 6482